High accuracy detection & quantification of PM2.5

  • High accurate detection
  • Small size
  • Maintenance-free

IAQ Sensor for PM2.5 detection

Detects PM2.5 that cannot be seen by the eye with a sensor.
It is commonly referred to as a dust sensor.
It outputs mass concentration (μg/m³) by high-precision
concentration conversion algorithm, then it's possible to visualize
IAQ (Indoor Air Quality).

MOVIE

Panasonic PM sensor introduction

What is PM2.5

PM2.5 is a general term for fine particulate matter of 2.5 μm or less suspended in the atmosphere.
It's impossible to see with the naked eye, and easy to penetrate deep into the respiratory tract. So, there are concerns about the effects on the human body.

  • Document about 「the fine particulate matter (PM2.5)」from Osaka Prefectural Department of Environment
  • Self servey data about hair

What is PM sensor

An optical sensor to visualize air quality that applies the phenomenon of scattering when light is applied to fine particles in the air

Features

Maintains long-term, high accuracy PM2.5 detection performance with a unique algorithm.

Maintain long-term performance by correcting parts whose performance deteriorates over time. Prevent wasteful operation of key components and extend their service life.

Maintenance-free by controlling stains

Intaking the air containing particulates into the sensor, however it's possible to control performance degradation by design of air flow structure so that the lens does not get dirty even after long-term use.

Multiple air quality detection

  • PM2.5, TVOC, eCO2,Temperature and Humidity detection
  • Small size
  • Maintenance-free

IAQ Sensor for Multiple detection NEW

Detects TVOC, eCO2, Temperature and Humidity in addition to
particulates (PM1.0, PM2.5 and PM10 ) in the air.
Various types of IAQ (Indoor Air Quality) can be visualized.

What's TVOC

TVOC (Total Volatile Organic Compounds) is a general term of VOC. VOC (Volatile Organic Compounds) is an abbreviation for organic compounds that are highly volatile and become gases in the atmosphere.

TVOC
https://www.umweltbundesamt.de/en/image/indoor-air-guide-values-for-tvoc-in-indoor-air

What's eCO2

eCO2 means the equivalent value of the concentration of CO2 estimated from TVOC.*

  • It does not measure CO2 itself

Features

TVOC, eCO2, Temperature and Humidity detection with small size

5 types of indoor air quality such as PM2.5 and TVOC can be measured and compact size (37x37x12mm) is achieved by miniaturizing the optical part.

TVOC (Total Volatile Organic Compounds)
eCO2 (estimated concentration of CO2)

Detects volatile organic compounds and measures indoor air quality. Calculate CO2 concentration from VOC emitted from the human body. Output the level values apply to IAQ standards on Federal Environment Agency of Germany (UBA).

Temperature and Humidity

Improvement of measurement stability and response is achieved by establishment protective layer on the sensor element of temperature and humidity detection.

Contributing to the miniaturization of the equipment to be installed

37x27x12mm of compact size, then it contributes to the miniaturization of the equipment to be installed.

Useful for simple communication and easy integration layout

In case of using a sensor for individual detection

Each of individual sensors needs to be installed, and a lot of space is required

In case of using a sensor for multiple detection

Space-saving and simple communication with one sensor

Line-up

Items Air Quality Sensor Remarks
For PM2.5 detection For multiple detection
Model No. SN-GCJA5 SN-GCQB1
Appearance
Input Voltage DC 5 V±10% DC 5 V±10%
Current consumption <100 mA <100 mA
PM Detectable size >0.3 μm >0.3 μm
Measurement Range 0 ~ 2000 µg/m³ (UART) 0 ~ 2000 µg/m³ (UART) -
0µg/m³ ~ (I²C) 0µg/m³ ~ (I²C) No upper limit
Accuracy ±10 % ±10 % 35~1000 µg/m³
±5 μg/m³ ±5 μg/m³ 0~35 µg/m³
TVOC*2 IAQ value*1 - Level 1 ~ 5 TVOC range
0.015 ~ 10 mg/m³
Accuracy - ±1 Actual value:±10%
eCO2*2 Output range - 400 ~ 5000 ppm Estimated value from TVOC
Accuracy*3 - (±20%) 2000~5000 ppm
- (±25%) 400~2000 ppm
Temp. Output range - -10 ~ 60 ℃
Accuracy*3 - (±0.4℃)
Humidity Output range - 0 ~ 95 %RH
Accuracy*3 - (±3%RH) 10%RH~90%RH
Lifetime*4 <5 years <10 years No cleaning required
Dimension 37×37×12(mm) 37×37×12(mm)
I/F I²C(3.3V)or
UART(3.3V、9600 bps)
I²C(3.3V)or
UART(3.3V、9600 bps)
  • IAQ standards by Federal Environment Agency of Germany(UBA).
    [Precautions for Use]
    If activated in an environment exceeding IAQ Level 1, a temporary offset may occur in the readings.
    The offset will be cleared once clean air at IAQ Level 1 is detected.
  • IAQ values and eCO2 characteristics after pre-powering for 48 hours in clean air.
  • The accuracy of eCO2, temperature, and humidity is for reference only.
  • Designed life under normal operating condition(continuous operation) under room temp. at 25℃, humidity 60% or less.
  • This product may generate noise depending on the method of its installation.

Application examples

Air quality detection devices can be used
in a variety of application units.

For the visualization of the air purification function
of an air purifier.

For the visualization of the air purification function
of an air conditioner.

For air quality monitoring in the HEMS (Home Energy Management System) field.