Switch-M16eG(PN28160/PN28160A) Release Note July 29, 2016: Version 1.0.0.153 - Resolved Issues: 1. CPU hang-up issue: CPU hangs may occur in the timing of packets transmission and reception. 2. The port number in MAC address table is displayed as "0" if it belongs to the member port of Link Aggregation. (Fixed to display "LAG-x", "x" means a link aggregation group ID.) 3. All MAC addresses in the MAC address table are displayed as "00:00:00:00:00:00" when the multiple processes refer the table at the same time. December 21, 2015: Version 1.0.0.148 - Specification Changes: 1.Order to upgrade Ping response performance. 2.Changed ARP treatment mechanism in order to upgrade CPU response performance. - Resolved Issues: 1. Enter the tftp commands include igress IP address for CLI have operation stop case. 2. Decrease the counter of "Discard packet" in Statistic. 3. Logout for telnet have operation stop case. 4. Failed write to file into update the firmware, failed to following action until reboot. - Reupdate the firmware - Display the syslog, Loopback history, save config information, information of "show tech detail". 5. Logout for ssh have can not login of ssh case. 6. Occurred repeatedly reset the port case. 7. Use TFTP have operation stop case. 8. Can not communicate from SW to different the network address devices in networks of plurality of network adresses are mixed. 9. To CLI do update the firmware from TELNET or SSH, these can not display the message of update complete. 10. Address learning of the port have operation stop case. Octorber 17, 2014: Version 1.0.0.136 - Specification Changes: 1. Initialize the IP adress & Subnet Mask of entry number when the Subnet Mask set the "0.0.0.0" in the "Telnet Access Limitation Configurationg. - Resolved Issues: 1. The following settings are not initialized to factory default if downloads a config file including these settings: - Port monitoring setting - Telnet setting - SSH setting - RADIUS server setting - IP setup interface setting - Syslog transmission setting - Exception handler setting 2. Memory issue: memory management issue in Telnet connection. 3. "Login method 2" is not executed when "Login method 1" is set as "RADIUS" and own IP address or IP address of RADIUS server is not set. 4. The gTagged-onlyh port can receive the "untag frame to itselfg. 5. Subnet Mask can't set the from 25 bit when IP address set the "0" at 4th octet in the "Telnet Access Limitation Configurationg. 6. IP address can not set the "255" at 4th octet in the "Telnet Access Limitation Configurationg. March 20, 2014: Version 1.0.0.118 First release.